808 / 640 nm · 30 / 0.5 W Fiber-coupled semiconductor laser
FS-LASER-808-640NM-30W
Select by wavelength, optical output, fiber and cooling. Laser optical output is not LPC receiver electrical output.


Parameters
| Center wavelength | 808±10 / 640±10 nm |
|---|---|
| Output power class | 30 / 0.5 W |
| Operating voltage | 5.6 / 2.25 V |
| Operating current | 11.8 / 0.9 A |
Optoelectronic test condition: 25°C water temperature. Operating-temperature limits are listed separately.
Applications & selection
PoF transmitters, source matching and laboratory platforms. Confirm wavelength, interface, driver, cooling and safety interlocks.
Pins & electrical interface
| Pin | Function | Pin | Function |
|---|---|---|---|
| 1 | NTC | 11 | 808+ |
| 2 | NTC | 12 | - |
| 3 | PD+ | 13 | - |
| 4 | PD- | 14 | - |
| 5 | Optical switch + | 15 | - |
| 6 | Optical switch − | 16 | - |
| 7 | Normally closed | 17 | - |
| 8 | Normally open | 18 | 808- |
| 9 | - | 19 | 640+ |
| 10 | - | 20 | 640- |
Optoelectronic parameters
| Parameter | Unit | Typ. 808 nm | Typ. 640 nm |
|---|---|---|---|
| Center wavelength | nm | 808±10 | 640±10 |
| Output power class | W | 30 | 0.5 |
| Threshold current | A | 1.8 | 0.55 |
| Operating voltage | V | 5.6 | 2.25 |
| Operating current | A | 11.8 | 0.9 |
| Slope efficiency | W/A | 2.94 | 1.11 |
| Electrical-to-optical efficiency | % | 45 | 22 |
Fiber specifications
| Parameter | Unit | Value |
|---|---|---|
| Fiber core diameter | μm | 200/400 |
| Fiber numerical aperture | - | 0.22 |
| Fiber length | m | - |
| Optical fiber interface | - | SMA905, detachable |
Environment & mounting
| Parameter | Unit | Min. | Typ. | Max. |
|---|---|---|---|---|
| Operating temperature | °C | 15 | 25 | 35 |
| Storage temperature | °C | -20 | — | 50 |
| Humidity | % | <70% at 25°C | ||
| Cooling options | - | Conduction cooling | ||
| Pin soldering time | s | <10 | ||
| Soldering temperature | °C | <280 |
Dimensions & mounting
Reference values support selection. Confirm final configuration and acceptance conditions in the technical agreement. A power class is not guaranteed output under every operating condition.