808 nm / 10 W Fiber-coupled semiconductor laser
FS-LASER-808NM-10W
Select by wavelength, optical output, fiber and cooling. Laser optical output is not LPC receiver electrical output.


Parameters
| Center wavelength | 808 nm |
|---|---|
| Output power class | 10 W |
| Operating voltage | 1.7 V |
| Operating current | 12 A |
Optoelectronic test condition: 25°C water temperature. Operating-temperature limits are listed separately.
Applications & selection
PoF transmitters, source matching and laboratory platforms. Confirm wavelength, interface, driver, cooling and safety interlocks.
Pins & electrical interface
| Pin | 1 | 2 |
|---|---|---|
| Function | LD- | LD+ |
Optoelectronic parameters
| Parameter | Unit | Min. | Typ. | Max. |
|---|---|---|---|---|
| Center wavelength | nm | 803 | 808 | 813 |
| Output power class | W | — | 10 | — |
| Threshold current | A | — | 1.3 | — |
| Operating voltage | V | — | 1.7 | — |
| Operating current | A | — | 12 | 14 |
| Slope efficiency | W/A | — | - | — |
| Electrical-to-optical efficiency | % | — | - | — |
Fiber specifications
| Parameter | Unit | Min. | Typ. | Max. |
|---|---|---|---|---|
| Fiber core diameter | μm | — | 200 | — |
| Fiber numerical aperture | - | — | 0.22 | — |
| Fiber length | m | — | - | — |
| NA(95%E) | - | — | 0.15 | 0.17 |
| Aiming wavelength | nm | — | - | — |
| Aiming optical power | mW | — | - | — |
| Aiming current | mA | — | - | — |
| Aiming voltage | V | — | - | — |
Environment & mounting
| Parameter | Unit | Min. | Typ. | Max. |
|---|---|---|---|---|
| Operating temperature | °C | 15 | 25 | 35 |
| Storage temperature | °C | -20 | — | 50 |
| Humidity | % | <70% at 25°C | ||
| Cooling options | - | Conduction cooling | ||
| Water tube dimensions | - | - | ||
| Flow rate | L/min | - | ||
| Optical fiber interface | - | Fixed fiber, SMA905, black 3 mm PVC jacket |
Dimensions & mounting
Reference values support selection. Confirm final configuration and acceptance conditions in the technical agreement. A power class is not guaranteed output under every operating condition.